Non-invasive absolute intracranial pressure value meter shown to be accurate in clinical settings

The results of independent clinical assessment – prospective study of innovative non-invasive absolute intracranial pressure (ICP) value (mmHg) meter were recently published in the journal Neurology (The official journal of the American Academy of Neurology). This is the first prospective comparative clinical study of a non-invasive ICP measurement method that shows accuracy and precision which is acceptable for clinical practice.

All previous non-invasive ICP measurement approaches based on correlation between some measured parameter of some anatomical structure with that of ICP, faced the need of calibration to the individual patient and thus failed to show acceptable accuracy and precision during prospective clinical assessments because of impossibility of patient specific calibration.

The study conducted in Neurology Clinics of Lithuanian University of Health Sciences (Kaunas, Lithuania), with the support of the European Brain-IT Research Group and Southern General Hospital (Glasgow, UK) clinically assessed the non-invasive ICP measurement device based on a specially designed two-depth transcranial Doppler (TCD) technique for simultaneously measuring blood flow velocity in the intracranial and extracranial segments of the ophthalmic artery (OA) while increasingly applying external pressure to the orbit - the same measurement principle as used for non-invasive arterial blood pressure measurement . Non-invasive ABP measurement does not need calibration to the individual patient in the same way as proposed non-invasive ICP absolute value measurement technology.

 

The clinical assessment, which is a fact of evidence - based medicine, demonstrated the non-invasive ICP meter’s precision and accuracy comparing with “gold standard” invasive cerebrospinal fluid pressure measurement via lumbar puncture. Paired measurement data were obtained from randomly selected neurological patients with different diseases and covering a wide range of different physiological and anatomical variation. The results obtained show for the first time that proposed non-invasive ICP measurement technology provides accurate and precise ICP measurement without the need for patient specific calibration. This is a break through point in attempts to create non-invasive absolute ICP value meter with sufficient accuracy and precision for use in routine clinical care.

Full text and source: News-medical.net